Programmable Logic Controller

KV-8000 series

Catalogs View Catalog

Camera input unit KV-CA02

KV-CA02 - Camera input unit

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

KV-CA02*1

General specifications

Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2
System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2

Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F
(no freezing)*3*4
System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F
(no freezing)*3*4

Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3
System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3

Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH
(no condensation)*3
System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH
(no condensation)*3

Operating environment

No dust or corrosive gas

Operating altitude

2000 m 6561.7' or less

Noise immunity

1500 Vp-p or more
Pulse duration: 1 μs, 50 ns (based on noise simulator)
IEC standard-compliant (IEC 61000-4-2/3/4/6)

Withstand voltage

1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)

Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

Vibration resistance

Intermittent vibration

Frequency 5 to 9 Hz

Half amplitude 3.5 mm 0.14"*5

Frequency 9 to 150 Hz

Acceleration 9.8 m/s2 32.2'/s2*5

Continuous vibration

Frequency 5 to 9 Hz

Half amplitude 1.75 mm 0.07"*5

Frequency 9 to 150 Hz

Acceleration 4.9 m/s2 16.1'/s2*5

Shock resistance

Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

Pollution degree

2

Performance specifications

Connectable CPU unit

KV-8000A

Max. number of connectable units

4

Number of ports

2

Supported camera models

KV-CA1H (Compact standard camera)
KV-CA1W (Wide-field high-resolution camera)

Cable length

5/10/20 m 16.4'/32.8'/65.6'*6

Recording time

Approx. 3 minutes*7

Internal current consumption

260 mA or less*8

Weight

Approx. 190 g

*1 for use with KV-8000 Series
*2 Supplied via the CPU unit or expansion unit.
*3 Guaranteed range in which the system can be used.
*4 Specified according to the temperature in the control panel on the lower side of the unit.
*5 Compliant with JIS B 3502 IEC 61131-2, Scan times: 10 times in each of the X, Y, and Z directions (for 100 min.)
*6 Lengths of the KV-C5/C10/C20 camera cables.
*7 Record time for one KV-CA1H with the following configuration of settings (initial value). The actual recording time varies depending on the number of devices, the frame rate, and the image quality settings. Frame rate: 30 fps/Quality: 3
In addition, the recorded video is cleared when the power is turned off.
*8 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal current consumption of the connected camera.

Other Models