High-Performance Micro Static Eliminators

SJ-M series

Catalogs View Catalog

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Spot Type Main Unit, Head Cable 2-m and CAB Needle SJ-M021G

SJ-M021G - Spot Type Main Unit, Head Cable 2-m and CAB Needle

  • CE Marking
  • CSA

Specifications

Model

SJ-M021G

Type

Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max.*1

Ion balance

±15 V or less*2

Supply pressure range

0.001 to 0.5 MPa*3

Min. air pressure

With SJ-ML

0.02 MPa (20 Nl/min)

With SJ-MS/ML1

0.03 MPa (20 Nl/min)

With SJ-MS/ML2

0.02 MPa (20 Nl/min)

With SJ-MS/ML3

0.08 MPa (50 Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +80 °C 32 to 176 °F*4*5

Relative humidity

35 to 65 % RH

Weight

Approx. 600 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %)
*2 Values obtained at an installation distance of 50 mm 1.97" and air flow rate of 20 Nl/min [ambient operating temperature +20 to +30 °C +68 to +86 °F, ambient operating humidity 40 to 60 % RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding +35 °C 95 °F. Use clean or dry air at a temperature of -20 °C -4 °F or less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40 °C 104 °F or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40 °C 104 °F.