Main controller Standard type GC-1000

GC-1000 - Main controller Standard type

  • CE Marking
  • UL Listing(c/us)
  • CSA

Specifications

Model

GC-1000

Input/output points

Safety inputs

16

Safety outputs

6

Safety relay output

-

AUX outputs

4

Test outputs

Maximum number of connectable expansion units

10*1

Maximum number of connectable remote I/O modules

4

GC-Link ports

2 ports

Safety input specifications

Input device

Contact output device or PNP output device

Input type

Type3

ON level (voltage/current)

Min. 11 V/2 mA

OFF level (voltage/current)

Max. 5 V/1.5 mA

Short-circuit current

Si 0 to 3: Approx. 5 mA
Si 4 to 15: Approx. 3 mA

Protection circuit

Surge protection circuit, wrong wiring protection circuit

Maximum cable length

Max. 100 m 328.1'

Safety output specifications

Output type

PNP transistor output (DC-13, Type 0.5, Protected outputs)*2

Maximum load current

500 mA

Residual voltage (during ON)

Max. 2.0 V

Leakage current (during OFF)

Max. 0.5mA

Maximum capacitive load

0.5 µF

Load wiring resistance

Max. 2.5Ω

Protection circuit

Overcurrent protection circuit, reverse connection protection circuit

Maximum cable length

Max. 30 m 98.4'

Safety relay output specifications

Output type

-

Rated load (resistance load)

Rated load (inductive load)

Relay output mechanical life

Maximum cable length

B10d

Test output specifications

Output type

PNP transistor output*3

Maximum load current

100 mA

Protection circuit

Overcurrent protection circuit, reverse connection protection circuit

Maximum cable length

Max. 100 m 328.1'*4

AUX output specifications

Output type

Transistor output (PNP/NPN selectable by wiring)
PNP output (DC-13, Type 0.1, Protected outputs)*2*3

Maximum load current

PNP: 100 mA, NPN: 20 mA

Residual voltage (during ON)

Max. 2.0 V

Leakage current (during OFF)

Max. 0.5 mA

Protection circuit

Overcurrent protection circuit, reverse connection protection circuit

Maximum cable length

Max. 30 m 98.4'

Communication interface

USB

USB2.0

Ethernet

100BASE-TX
STP (shielded twisted pair) cable of Category 5 or higher

Network functionality

EtherNet/IP™ *5, PROFINET, Modbus/TCP, MC protocol, UDP

Others

LCD display

1.77-inch color LCD

Display buttons

4 points (3 operation keys + 1 BACK key)

Applicable standards

EMC

EMS: IEC 61131-2/-6, EN61131-2/-6
EMI: IEC 61131-2, FCC Part15B Class A,
ICES-003, Class A

Safety

IEC 61508,EN61508 SIL3
IEC 62061,EN62061 SIL CL3
ISO/EN13849-1:2015 Cat. 4, PL e

Dimensions

60×95×90 mm 2.36"× 3.74"×3.54" (W×D×H)

Power supply

Power voltage

24 VDC (-30 to +20%) Class 2

Power consumption

Max. 200 mA

Environmental resistance

Ambient temperature

−10 to +55 °C 14 to 131 °F (No freezing)

Storage temperature

−25 to +70 °C -13 to 158 °F (No freezing)

Relative humidity

5 to 85% (No condensation)

Operating altitude

Max. 2000 m 6561.7'

Overvoltage category

II

Pollution degree

2

Vibration resistance

Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14"
Frequency: 9 to 150 Hz, Acceleration: 10 m/s2
10 times each in X, Y, Z directions

Shock resistance

Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions

Material

Polycarbonate

Weight

Approx. 260 g

*1 The bus extension unit “GC-B30” is not included in this number, and only one set of “GC-B30” can be used per setup.
*2 Paragraph 6.4.6 Temporary overload of IEC 61131-2 supports up to 1.2 times the maximum load current.
*3 AUX outputs (NPN output) and test outputs do not comply with paragraph 6.4.6 of IEC 61131-2.
*4 When the test output is branched and connected to multiple safety input devices, the total branched cable length must not exceed 400 m 1312.3'.
*5 EtherNet/IP™ is a trademark of ODVA. inc.

Other Models