Safety Relay Terminal GL-T11R

GL-T11R - Safety Relay Terminal

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

GL-T11R

Applicable model

GL-R Series

Relay output

FSD1,2

250 VAC 6 A 30 VDC 6 A (Resistance load)
240 VAC 2 A (COSø=0.3) (Inductive load)
24 VDC 1 A (COSø=0.3) (Inductive load)

Life-span

Electrical life-span

100,000 cycles or more with 250 VAC 6 A resistance load
(open/close frequency: 20 times/minute)
100,000 cycles or more with 30 VDC 6 A resistance load
(open/close frequency: 20 times/minute)
500,000 cycles or more with 250 VAC 1 A resistance load
(open/close frequency: 30 times/minute)
500,000 cycles or more with 30 VDC 1 A resistance load
(open/close frequency: 30 times/minute)
AC15: 100,000 cycles or more with 240 VAC 2 A inductive load
(open/close frequency: 20 times/minute, cosø = 0.3)
DC13: 100,000 cycles or more with 24 VDC 1 A inductive load
(open/close frequency: 20 times/minute, L/R = 48 ms)

Response time

ON→OFF

GL-R +10 ms

OFF→ON

GL-R +32 ms

Supplemental output
(Non-safety-related output)

AUX

Transistor output (PNP/NPN input device can be connected.)*1
50 mA max., residual voltage 2.5 V max.
(When the cable between the GL-R and GL-T11R is 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: [Power supply voltage - 5 V] to [Power supply voltage]
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA
(Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±10%, ripple (P-P) 10% or less, Class 2

Current consumption.

100 mA max. (24 VDC, GL-T11R only)

Approved standards

EMC

EMS

EN61496-1, UL61496-1, IEC61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

EN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE)
EN ISO13849-1 : 2015 (Category4, PLe)
UL508, EN50178

Environmental resistance

Enclosure rating

IP20 (IEC60529)
Must be installed within a control panel rated at IP54 or higher.

Pollution degree

2

Overvoltage category

III

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage relative humidity

15 to 95 % RH

Altitude

2,000 m or less

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Polycarbonate

Weight

Approx. 310 g

*1 The output operation is the same as that when the PNP output type cable is used.