CCD Laser Displacement Sensor

LK series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Sensor Head, Wide Spot LK-036

LK-036 - Sensor Head, Wide Spot

  • CE Marking

Specifications

Model

LK-036

Type

Sensor head High-precision Sensor head

Reference distance

30 mm 1.18"

Measuring range

±5 mm ±0.20"

Light source

Type

Visible red semiconductor laser

Wavelength

670 nm

Output

0.95 mW

Laser
Class

FDA (CDRH) 21CFR Part 1040.10

Class 2 Laser Product

IEC 60825-1

Spot diameter (at standard distance)

Approx. 30 x
850 µm
0.001181 x 0.0335"

Linearity

±0.1% of F.S. *1

Repeatability

1 µm *2 0.000040"

Analog output

Voltage output

±5 V
(1 µm 0.000040"/mV) *3

Impedance

100 Ω

Current output

4 to 20 mA (Applicable load: 350 Ωmax.)

Alarm output

NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max.

Sampling cycle

512 µs

Other functions

Auto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment of mirror surface measurement mode, changing the sampling cycle

Temperature characteristics

0.01% of F.S./°C

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Maximum current consumption

400 mA max.

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent or fl uorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F (No condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g (including cable)

*1 Linearity was obtained using KEYENCE's standard target (Zirconia block gauge: LK-031/036, LK-081/086, LK-011, White ceramic block gauge: LK-503).
*2 Repeatability was obtained using KEYENCE's analog sensor controller (RD-50) with the number of averaging measurements set to 64.
Note: The ripple of the analog output may be 1 mV or more due to common mode noise when observed with an oscilloscope or a high-speed A/D conversion board.
*3 When measurement is impossible, 12 V (31.2 mA) is output.

Other Models