High-Speed, High-Accuracy CCD Laser Displacement Sensor

LK-G3000 series

Catalogs View Catalog

Sensor Head: Long Distance, Wide beam LK-G157

LK-G157 - Sensor Head: Long Distance, Wide beam

  • CE Marking

Specifications

Model

LK-G157

Reference distance

Diffused reflection: 150 mm 5.91", Specular reflection: 147.5 mm 5.81" (Specular reflection)

Measuring range

Diffused reflection: ±40 mm ±1.57", Specular reflection: ±39 mm ±1.54"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. 120 x 1,700 µm
0.0047" x 0.0669"

Linearity

±0.05 % of F.S. (F.S.= ±40 mm ±1.57")*3

Repeatability

0.5 µm 0.000020"*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -9 -0.35" (NEAR side) to -15 mm -0.59" (NEAR side) for Diffused reflection, and -8.7 -0.34" (NEAR side) to -14 mm -0.55" (NEAR side) for specular reflection.
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.