Raw data output controller LJ-X8000A

LJ-X8000A - Raw data output controller

  • CE Marking
  • CSA

Specifications

Model

LJ-X8000A

Head input

Up to 1 head
Compatible with LJ-X8000 series heads and LJ-V7000 series heads

Sampling cycle (trigger interval)

When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs) *1
When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs) *2
(Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs)) *3

Interface

Control input

Supports the batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP).

Control output

•Supports the trigger ready (READY) and system error (ERROR).
•Photo MOSFET*4

Synchronous input / output

For trigger synchronization of multiple controllers*5

Ethernet

Supports the profile output, setting, controll, 1000BASE-T/100BASE-TX*6

Encoder input

One system
RS-422 line driver output (with 5 V output: Up to 150 mA),
Open collector output (5 V / 24 V compatible) combined use

Response frequency

RS-422

Single phase/Z-phase : 1.6 MHz
2-phase/1-multiplier : 1.6 MHz
2-phase/2-multiplier : 3.2 MHz,
2-phase/4-multiplier : 6.4 MHz

Open collector (OC)

Single phase/Z-phase : 100 kHz
2-phase/1-multiplier : 100 kHz
2-phase/2-multiplier : 200 kHz,
2-phase/4-multiplier : 400 kHz

Laser ON input

Non-voltage Input (a short circuit via the short pin at the time of shipment from the factory)

Ratings

Power voltage

24 VDC±10%

Maximum current consumption

1.3A

Environmental resistance

Ambient temperature

0 to + 45 °C (DIN rail mounting) / 0 to + 40 °C (side mounting)

Relative humidity

35 to 85% RH (No condensation)

Weight

Approx. 700 g

*1 When the measurement range is narrowed in accordance with the binning settings.
*2 When the measurement range is set to minimum, binning is ON, and parallel imaging is ON. All other settings are default values.
*3 When binning and parallel imaging are both ON. All other settings are default values.
*4 Both plus common connection for NPN input devices and minus common connection for PNP input devices are possible.
*5 Dedicated to synchronous I/O between controllers (LJ-X8000A).
*6 The communication library (DLL) and the sample program are included in the PC application (LJ-H2X).