Specifications

Model

FS-V21RM

Type

Main unit: 0-line

Light source LED

Red LED

Response time

250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /500 µs (HIGH RESOLUTION) /50 µs (HIGH SPEED)

Output selection

Light-ON/Dark-ON selectable

Detection mode

Light intensity/rising edge/falling edge

Shift function

Max. ±1,999 (variable)

Timer function

Mode

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, selectable

Variable range

1 to 500 ms
[1 to 30 ms (in 1 ms increments), 30 to 50 ms (in 2 ms increments), 50 to 200 ms (in 10 ms increments), 200 to 500 ms (in 50 ms increments)]

Accuracy

±10 % of the Preset Value

Control output

100 mA max. (40VDC max), Residual voltage: 1Vmax.

Monitor output

1 to 5 load resistance to display 0 - 495 for FINE and TURBO. Voltage output: 1 to 5 V, Load resistance: 10 kΩ min., Repeatability: ±0.5 % of F.S.*1

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Power consumption

Normal

S-APC OFF: 650 mW max.(27 mA max. at 24 VDC), S-APC ON: 720 mW max.(30 mA max. at 24 VDC)*2

ECO half

S-APC OFF: 530 mW max.(22 mA max. at 24 VDC), S-APC ON: 660 mW max.(25 mA max. at 24 VDC)*2

ECO all

S-APC OFF: 480 mW max.(20 mA max. at 24 VDC), S-APC ON: 550 mW max.(23 mA max. at 24 VDC)*2

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Size

30 mm (H) x 9 mm (W) x 70 mm (D) 1.18" (H) x 0.35" (W) x 2.76" (D)

Weight

Approx. 80 g (including 2-m cable)

*1 Use the FS-V21RM in the FINE or TURBO mode when outputting signals with a monitor.
*2 S-APC will be always turned ON when the high-resolution or high-speed mode is selected. S-APC is by default set to OFF in any other mode.
*3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: –10 to +50 °C 14 to 122 °) 11 to 16 Units: –10 to +45 °C 14 to 113 °F